How Thermal Runaway Spreads Through an EV Battery Pack
Thermal runaway can spread when a failing cell transfers heat, flame or hot gases to nearby cells. Pack design works to interrupt those paths.
The short answer: Thermal runaway spreads when heat or hot material from a failing cell raises neighboring cells to dangerous temperatures. Cell spacing, barriers, cooling paths and venting can slow that transfer, but their effectiveness depends on the pack’s design and the failure conditions.
Thermal runaway can spread from one battery cell to its neighbors when heat, flames or hot gases raise those cells to dangerous temperatures. Pack designers try to interrupt that transfer with spacing, barriers, cooling systems and paths that direct vented gases away from other cells. These measures can slow propagation, but they do not make every failure impossible to spread.
A battery pack contains many cells connected into modules or other structural groupings. In normal operation, the cells store and release energy through controlled electrochemical reactions. A cell in thermal runaway has entered an uncontrolled, self-heating failure. As its temperature rises, internal reactions can release more heat, which can further accelerate the failure.
The key question is how that energy reaches nearby cells. Heat can move through solid materials, through air and gases, or through direct contact with flames and hot ejecta. A pack’s structure determines which paths are open and how quickly they can carry energy.
How a failing cell transfers heat
Conduction through contact points
Conduction transfers heat through materials that touch. Cells may be close together, and their sides can exchange heat through contact, through a module frame, or through materials that hold them in place. A hot cell can also heat shared structural parts, which then pass energy to neighboring cells.
This path matters because the pack’s structure can connect cells thermally even when their surfaces do not touch directly. A metal support or shared component may carry heat across a wider area. Insulating layers and deliberate gaps can increase resistance to that transfer, although the same structures also have to support and protect the pack.
Convection from hot gases
As a cell fails, it can vent hot gases and other contents. Those gases can move through spaces in a module or pack, carrying heat to neighboring cells. If they collect near another cell, or flow across its surface, they can warm it. The path depends on how the pack channels gases and whether vents allow them to escape.
Venting is therefore a thermal design issue as well as a pressure-management issue. A route that directs gases out of the pack can reduce exposure of nearby cells. A poorly placed or obstructed route could instead send hot gases toward other cells or pack components.
Radiation and direct flame contact
Hot surfaces can transfer energy by radiation across a gap. This means cells do not need to touch for one to heat another. If a failure produces flames, direct flame contact can deliver intense heat to nearby surfaces. Hot particles or expelled material can also land on neighboring cells and create concentrated heating.
These paths can act together. A cell may heat a shared support by conduction while hot gases move through the module and radiation crosses open space. A design that addresses only one route may leave other routes available.
Why neighboring cells can also fail
A neighboring cell does not need to experience the same initial fault as the first cell to become involved. If enough heat reaches it, its temperature can rise until internal processes become unstable. If that cell enters thermal runaway, it becomes a new source of heat and hot gases. The event can then continue from cell to cell.
Propagation is not automatic. It depends on factors such as the failing cell’s heat release, the distance and materials between cells, the gas flow paths, and how effectively the pack can carry heat away. The same pack may also behave differently under different failure conditions. That is why a single design feature cannot be treated as a guarantee that a failure will stop at one cell.
Pack-level protection has to consider both the energy leaving the failing cell and the ability of neighboring cells to tolerate or shed the heat they receive. The aim may be to prevent a neighboring cell from reaching a critical condition, delay that point, or guide the consequences away from other parts of the pack.
Design measures that can slow propagation
Spacing and thermal barriers
Increasing separation between cells can reduce direct contact and create more room for insulation or airflow. Barriers between cells can resist conduction and shield neighboring surfaces from radiant heat, flame or expelled material. Their placement matters: a barrier must cover the relevant path, and it must retain its protective role when exposed to heat and pressure.
Spacing and barriers also interact with packaging. Cells must fit within the available structure, and the pack must provide mechanical support and manage normal operating heat. Designers balance these needs while limiting the routes by which one failed cell can heat another.
Cooling and heat removal
Cooling systems are intended to manage heat during normal use, and heat-removal paths can also affect how energy moves during a failure. A cooling plate or other shared component may draw heat away, but a connected structure can also conduct heat toward nearby areas. Its behavior depends on its layout and on whether the cooling system remains effective in the failure scenario.
Thermal management should therefore be understood as part of the pack’s full heat-transfer design. The question is not simply whether cooling exists, but where heat can flow, what components connect cells, and how much heat those paths can remove or redirect.
Venting and gas routing
Purposeful vent paths can direct hot gases away from neighboring cells and toward an exit from the module or pack. This can reduce convective heating and limit the chance that flame or hot material reaches another cell. The route needs to account for where gases emerge and where they are discharged.
Venting also involves tradeoffs. Openings and channels must work within the pack structure, and a route that is not isolated from other cells may expose them to the very gases it is intended to manage. The design goal is controlled movement, not simply creating an opening.
Pack layout and containment
Cell arrangement determines which cells are neighbors, how close they are, and which structural components they share. Module boundaries and pack enclosures can help contain a local event or direct its effects, while shared structures can carry heat between sections. Layout choices influence how many neighboring cells are exposed to the initial failure.
Containment is not the same as eliminating the energy released by a failing cell. It is a way to limit where that energy travels and to give protective measures time to work. A pack may combine cell spacing, insulating components, cooling features and gas channels because each addresses a different transfer path.
What pack design can and cannot establish
Thermal runaway illustrates why battery safety is a system-level problem. Cell chemistry and construction matter, but so do the module supports, cooling arrangement, barriers, vents and pack enclosure. A feature that improves one part of the response may affect another path, so designers have to evaluate the complete arrangement.
For drivers, the practical point is that a battery pack is engineered to manage heat and limit the spread of a cell failure. The presence of a particular feature alone does not show how a pack will respond in every event. A meaningful assessment depends on the full design and evidence about how it performs under defined conditions.
When a cell enters thermal runaway, energy can reach its neighbors through solid contact, hot gases, radiation, flame or expelled material. Pack design slows propagation by breaking those connections, removing heat and routing hot products away. How well those measures work depends on how the measures fit together across the pack.
Frequently asked questions
What makes thermal runaway spread between cells?
Heat can reach neighboring cells through conduction in touching or shared materials, convection from hot gases, radiation across gaps, and direct exposure to flames or expelled material.
Does thermal runaway always spread through a battery pack?
No. Propagation depends on the heat released, cell spacing and materials, gas flow paths, and how effectively the pack removes or redirects heat.
How can battery pack design slow thermal runaway?
Design measures include spacing cells, adding thermal barriers, managing heat with cooling features, and routing vented gases away from neighboring cells.
Can cooling alone stop thermal runaway from spreading?
Cooling is one part of the design. Shared components can also conduct heat, and hot gases, radiation or flames may use other paths, so the whole pack layout matters.
Related stories
Gross vs. Usable EV Battery Capacity, Explained
An EV’s gross battery capacity describes its full energy reserve; usable capacity is the portion the driver can draw on. Here’s how to compare the terms.
How EV Battery Chemistry Affects Charging, Range, and Aging
LFP, NMC, and other lithium-ion chemistries shape an EV’s energy storage, charging behavior, durability, and material tradeoffs in different ways.
How to Read an EV Battery Health Report
Battery health reports can help used EV shoppers assess capacity, but one reading is only a snapshot. Learn what common metrics mean and what to ask next.